Size an indication
- Open Measure and the Indications tab.
- Choose Size indication (click) and click on the indication. Clearshot grows a region from the click and outlines it.
- Read its length, width, area, equivalent diameter and contrast.
- If the outline is not right, adjust the threshold and polarity and click again, or Re-run with the current threshold.
Projected porosity
Draw a Reference area box. Clearshot reports projected porosity as a percentage of that area, from the indications inside it.
Advisory rule check
Under Acceptance limits (advisory), enter a name and source (for example "Level 2" and "ISO 10675-1"), the thickness t (blank uses the wall measurement) and any of these limits: max single length, max single width, max pore Ø (mm or × t), max porosity %, max number, max accumulated length.
The check shows within or exceeds, line by line, and lists anything it still needs. It advises only. Your Level 2 or 3 decides. Clearshot does not contain acceptance standards; you enter the limits from the code you work to.